Air Quality Devices – Comparison 2017 Q2

More and new devices on the market. From wearables to home AQI monitors are here to assist people’s needs. Remember air pollution is everywhere.

comparison air 2017 Q2

  • Prices may vary during time.
  • Some Companies don’t specify on their data sheet if their devices are capable to measure PM2.5 or PM10 and they just mention the word dust.
  • Some other companies say: Our product goes beyond CO₂ by analyzing substances that directly affect your well-being by measuring VOCs. They aren’t clear if their devices have CO₂ sensor.
  • Some of the devices are AQI Monitors and Air Purifiers Combo. On this list you can only read the features as an AQI monitor.
  • The classification of the design between BadGood and Very Good is based on the materials (plastic, wood, glass and metal) that they use and the aesthetic on my personal opinion.

CO2 Candles Experiment

CO2 Candles Experiment

In this experiment I will demonstrate how fast Carbon Dioxide CO2 rises inside a room by lighting two small candles.

bedroomday1_0000 copy

I chose my study room as it can be easily isolated, plus I have got all the AQI monitors inside this room for the purpose of the experiment. The room is 7.3m². The experiment is easy, I lit 2 candles and closed the door and window of the room. Then I waiting with myself inside the room till the CO2 reached 1200ppm. Basically I logged the time when the CO2 was 430ppm and when it reached the 1200ppm with and without the candles.

With the candles the CO2 needed 35 minutes to reach the 1200ppm limit as you can see on the graph below and without any candle and with exactly the same conditions as before the CO2 needed 59 minutes to reach the upper limit.

Conclusion

You gain 25 minutes of more oxygen and less CO2 until the room reaches the 1200ppm limit which means more productive time and fewer headaches.

Gray Slate

Where are the Public Air Quality Stations?

In my city (Almeria, Spain) there are two stations that measure the local Air Quality.

Let’s analyze them and see if they are located in the correct places and if they feature the necessary instruments for measuring the AQI properly.

The Background

It is located in “El Boticario” a park 10km outside of the city center. The coordinates according to an official document from“Junta de Andalucía” are UTMX:554439 and UTMY:4080272, but they aren’t correct (Not so professional). The real coordinates are UTMX:554319 and UTMY:4080066. This station seems to work well although they don’t feed the data in real time to the public and quite often is down.

Read More »